Skip to content
Back to Solar Energy
Solar Energy

Solar Electricity Price Assumptions: Test the Sensitivity

Test solar electricity price assumptions by changing import and export values separately, using a transparent ten-year sensitivity example.

Arshia Jahangiri
3 min

Table of contents

Listen to this article

Solar electricity price assumptions can strengthen or weaken a Canadian homeowner’s financial estimate. Test them as scenarios rather than treating rising rates as guaranteed. The important question is which avoided charge or export value changes, not simply whether electricity is expected to become more expensive.

This sensitivity exercise changes one input at a time. It is separate from building a complete year-by-year ownership model and does not forecast tariffs or promise an improved payback.

Identify the value that could change

Self-consumed generation can avoid applicable electricity charges. Exported generation may receive a different credit or payment under the utility arrangement. Some charges remain regardless of how much the panels produce.

The OEB’s Ontario guidance explains that net-metering credits apply to consumption-related charges rather than every bill charge. That is a jurisdiction-specific example of why a headline rate increase cannot automatically be multiplied by all solar generation.

Write three separate inputs: avoidable import value, usable export value and remaining charges. Check the current account terms before deciding which input a proposed price scenario affects.

Establish an unchanged base case

Use deliberately invented quantities: 2,000 kWh used directly at $0.15 per kWh and 3,000 kWh exported at a usable $0.10 per kWh. Those components initially provide $300 and $300 of gross value, or $600 combined.

For this exercise only, hold production, the self-use split and usable exports constant for ten years. Exclude operating costs, repairs, financing, tax, degradation and discounting so the effect of the chosen price assumption is visible. This simplified base is not a realistic complete forecast.

Change only the avoided import value

Keep exports worth $300 each year. Apply the annual price-change assumption only to the starting $300 self-use component, using powers zero through nine. The first year therefore stays the same in every scenario.

Annual change in avoided import value Ten-year self-use value Ten-year export value Combined gross value
−2% $2,743.91 $3,000 $5,743.91
0% $3,000.00 $3,000 $6,000.00
+2% $3,284.92 $3,000 $6,284.92

The self-use calculation is $300 multiplied by the sum of (1 + assumed annual change) raised to powers zero through nine. These are nominal gross dollars, not profit, present value or current tariff offers.

The example’s increasing-price case adds about $284.92 relative to the flat case, because only part of the generation value was changed. Escalating every generated kWh would answer a different question.

Run an export-value test separately

Next, keep the import assumption unchanged and change the usable export value or credit utilization. Ask what happens if less credit can be used, the household’s consumption changes or the relevant arrangement applies a different value.

Do not assume imports and exports follow the same escalation formula unless the actual terms support it. Keep any rule change as an explicit scenario with its source, rather than silently inserting a favourable future arrangement.

Put costs back into the full model

After isolating the price effect, restore operating costs, replacement assumptions and the initial investment. Explain any ownership-cost escalation instead of increasing electricity benefits while keeping every expense artificially unchanged.

For discounted analysis, keep the price and discount assumptions consistent and state their basis. Borrowing costs and mandatory payments need their own rows. A scenario with more nominal electricity value does not automatically provide greater household liquidity when costs occur.

Ask for the flat-price comparison

If a quote’s business case depends heavily on escalating rates, request a flat-value case and a less favourable case using the same scope. Record what changes the decision and what further evidence would narrow uncertainty.

The solar financial-model guide supports the implementation task. This exercise supplies a controlled sensitivity check, helping you see whether a projected improvement comes from the installation or from an optimistic electricity-price assumption.

Share this article